ABSTRACT
The flow nozzle was constructed based on the dimensions and
specifications of the international standard organization (I.S.O)
recommendation.
Throat diameter 42.5mm
Length converging nozzle 68mm
Thickness of nozzle 2mm
Diameter of major axis of
ellipse 85mm
Diameter of minor axis of
ellipse 56.6mm
Diameter of duct pipe 85mm
The absence of this device (Nozzle) has imposed a very big problems to early
scientist. This had existed due to the difficulties in measuring fluid flow in
channel.
These scientist latter came out
with different kinds of nozzle which facilitates measurement. They were
convergent, divergent and divergent-convergent nozzle.
Other metering devices include
venturi meter orifice meter, weir etc. each of them has different
structures and mode of operation.
The constructed electric is
attached to an upstream pipe to give a substantial steady flow to the down
stream pipe. Fouling and head loss should be minimized likewise eddies
formation. Lastly, the same diameter of tube should be used to replace
themanometric tube when it got broken. Likewise the fluid should be maintained.
TABLE OF CONTENT
CHAPTER ONE
1.0
INTRODUCTION
1.1
SCOPE OF THE
PROJECT
CHAPTER TWO
2.0
HISTORICAL REVIEW OF
FLOW
2.1
THEORY OF FLOW
METER
2.2
VENTURING
METER
2.3
ORIFICE
METER
2.4
FLOW
NOZZLE
2.5
TYPES OF FLOW
NOZZLE
2.6
CHARACTERISTICS OF FLOW
NOZZLE
2.7
ADVANTAGES OF FLOW
NOZZLE
2.8
DISADVANTAGES OF FLOW
NOZZLE
CHAPTER THREE
3.0
MATERIAL OF
CONSTRUCTION
3.1
CONSTRUCTION
CHAPTER FOUR
4.0
DISCUSSION
4.1
RECOMMENDATION
4.2
CONCLUSION
4.3
REFERENCE
4.4
NOMENCLATURE
SCOPE OF THE PROJECT
The aim of this project is to construct a flow nozzle capable of
conveying fluid (liquid) from one point to the other. The parameter used depict
the pressure change, the velocity and quantity of flow is also inclusive. The
nozzle should be able to create a pressure drop in moving fluid and give the
quanity of fluid that flow through for a given period of time. The nozzle
should be capable of satisfying industrial requirement when placed in process
plant for fluid supply.
The flow nozzle fabricated was
based on the following prescriptions.
Throat diameter
42.5mm
42.5mm
Length of converging
nozzle
68mm
The thickness of the
nozzle
2mm
Diameter of ellipse major
axis
85mm
Diameter of ellipse minor
axis
56.6mm
Diameter of the duct
(pipe0
85mm
CHAPTER ONE
1.0 INTRODUCTION
The study of fluid behaviour is very important in process
engineering. It constitutes the study of unit operation. The branch of
engineering that deals with the study of fluid is called fluid machines. An
understanding of fluids through pipe, pumps and all kind of process equipment
and also for the study of heat flow and pressure change. The branches of fluid
machines include fluid static and fluid dynamics fluid static treats fluids in
the equilibrium state of no shear streets while fluid dynamics deals with
position of fluid in motion relative to other part.
A fluid is a substance that
foes not permanently resist distortion. An attempt to change the shape of a
mass of fluid result inlayers of fluid scliding over one another until a new
shape, shear stress exist, the magnitude of it depend on the viscosity of the
fluid and rate of sliding but when final shape is reached, all shear stress
will have disappeared.
The term flow means volume per
unit time at specified temperature and pressure conditions.
It can be measured using
positive displacement meter or rate meter. The term fluid is a generalized name
given to liquid and gases. Fluid flow or is transported from one place to
another by different means either by container gallon, cylinder,
tank the related means to the topic at and now is
transportation by pipe.
Pile consist of nozzles and
ducts through which liquid flow. A nozzle is a mechanism which kinetic energy
of fluid is converted and increased in an adiabatic process.
T his process accompanies
decrease in pressure and change in flow area of the fluid.
The variation in shape and
diameter of different part of nozzle effect the flow of fluid nozzle comes in
different types, we have divergent nozzles, convergent nozzles and
divergent-convergent nozzles.
The rate of flow of fluid in
pipe is measured by devices which facilitates the ascertainment of the volume
of fluid flowing in a unit time. These devices are collective called flow meter
or rate meters.
Flow meters are of different
types such as venturi-meter, flow nozzle, orifice meter, rofa meter and weirs
these devices are used as choice. All the devices mentioned above facilitates
movement of fluid on specified direction, speed and size.
Department | Chemical Engineering |
Project ID Code | CHE0060 |
Chapters | 3 Chapters |
No of Pages | 44 pages |
Methodology | Scientific Method |
Reference | YES |
Format | Microsoft Word |
Price | ₦4000, $15 |
|
|
Contact Us On | +2347043069458 |